Image sampler
Type - specifies the image sampler type:
Fixed - this sampler always takes the same number of samples per pixel;
Adaptive QMC - this sampler takes a variable number of samples per pixel depending on the difference in the intensity of the pixels;
Adaptive subdivision - this sampler divides the image into an adaptive grid-like structure and refines depending on the difference in pixel intensity.
*********
Antialiasing filterThis section allows you to choose an antialiasing filter. All standard 3ds Max filters are supported with the exception of the Plate Match filter...
*********
Fixed image samplerThis is the simplest image sampler, and it takes a fixed number of samples for each pixel.
Subdivs - determines number of samples per pixel. When this is set to 1, one sample at the center of each pixel is taken. If this is greater than 1, the samples are distributed within the pixel. The actual number of pixels is the square of this parameter (e.g. 4 subdivs produce 16 samples per pixel).
Adaptive QMC sampler
This sampler makes a variable number of samples per pixel based on the difference in intensity between the pixel and its neighbors.
This is the preferred sampler for images with lots of small details and/or blurry effects (DOF, motion blur, glossy reflections etc). It also takes up less RAM than the Adaptive subdivision sampler.Min subdivs - determines the initial (minimum) number of samples taken for each pixel. You will rarely need to set this to more than 1, except if you have very thin lines that are not captured correctly, or fast moving objects if you use motion blur. The actual number of pixels is the square of this number (e.g. 4 subdivs produce 16 samples per pixel).
Max subdivs - determines the maximum number of samples for a pixel. The actual maximum number of sampler is the square of this number (e.g. 4 subdivs produces a maximum of 16 samples). Note that V-Ray may take less than the maximum number of samples, if the difference in intensity of the neighbouring pixels is small enough.
Use QMC sampler threshold - when this is on (the default), V-Ray will use the threshold specified in the QMC sampler to determine if more samples are needed for a pixel. When this is off, the Color threshold parameter will be used instead.
Color threshold - the threshold that will be used to determine if a pixel needs more samples. This is ignored if the Use QMC sampler threshold option is on.
Show samples - if this is on, V-Ray will show an image where the pixel brightness is directly proportional to the number of samples taken at this pixel. This is useful for fine-tuning the antialiasing of the image.
*********
Adaptive subdivision sampler
This is an advanced image sampler capable of undersampling (taking less than one sample per pixel). In the absence of blurry effects (direct GI, DOF, glossy reflection/reftaction etc) this is the best preferred image sampler in V-Ray. On average it takes fewer samples (and thus less time) to achieve the same image quality as the other image samplers. However, with detailed textures and/or blurry effects, it can be slower and produce worse results than the other two methods.
**Also note that this sampler takes up more RAM than the other two samplers.Min. rate - controls minimum number of samples per pixel. A value of zero means one sample per pixel; -1 means one sample every two pixels; -2 means one sample every 4 pixels etc.
Max. rate - controls maximum number of samples per pixel; zero means one sample per pixel, 1 means four samples, 2 means eight samples etc.
Color threshold - determines the sensitivity of the sampler to changes in pixel intensity. Lower values will produce better results, while higher values will be faster, but may leave some areas of similar intensity undersampled.
Randomize samples - displaces the samples slightly to produce better antialiasing of nearly horizontal or vertical lines.
Object outline - this will cause the image sampler to always supersample object edges (regardless of whether they actually need to be supersampled). This option has no effect if DOF or motion blur is enabled.
Normal threshold - this will supersample areas with sharply varying normals. This option has no effect if DOF or motion blur is enabled.
Show samples - if this is on, V-Ray will show an image where the pixel brightness is directly proportional to the number of samples taken at this pixel. This is useful for fine-tuning the antialiasing of the image.
0 comments:
Post a Comment